Turck RFID interface

Turck RFID tag memory read, write and dedicated debug driver

Open the plugin

Enter “Development Configuration → Collection Configuration”, create a device and select “TurckRfidMaster” in “Collection Plugin”.

Supported channels and data types

Channel typePre-configuration check
TCP ClientConfirm network reachability of the device IP, port, and gateway to the device.

Optional data types: Boolean, Byte, Int16, UInt16, Int32, UInt32, Int64, UInt64, Float, Double, String

This list describes types allowed by the plugin editor. Address width, arrays, string length and read/write restrictions still follow this page; it does not mean that every address supports every type.

Address rules

  • Turck RFID Reader addresses use decimal tag byte positions, such as 0, 8, 120.
  • Boolean must use BYTE.bit explicitly, the bit number range is 0 to 7, for example 10.3.
  • The first read and write will read the tag UID, block number and block size; reinitialize after each TCP reconnect or no tag error.
  • A maximum of 64 tag data bytes can be read and written in a single frame, and larger ranges are automatically packetized by the driver.

Special methods

MethodPurposeParameters
ReadTagInfoAsyncRead tag informationNo parameters

Device debug

Enter “Development Configuration → Collection Configuration”, select the current device then open “Protocol Debug” at the top of the workspace.

Dedicated debugging page

The protocol debug page is used to read, write, and inspect RFID tag memory.

Debugging notes

The dedicated page verification can be completed by reading the tag inventory information. There is no writing operation on the current page.

Functions

FunctionPurpose
Read or monitorRead current values or monitor the latest device update.
Common read/write debugUse Common read/write debug with an approved test point and confirm site safety before execution.

Verify the configuration

Read byte 0 of the same tag in a tag tool and compare value/UID; keep the tag fixed when reading subsequent bytes.

Writes and control operations require an approved test point and the site safety procedure.

Troubleshooting

  • Byte offsets differ from Boolean byte.bit addresses. Transfers use 64-byte fragments; validate tag presence/initialization before widening the range.
  • Special method execution fails: Check method parameters and permissions; control, write or reset methods also need to confirm that the device is in a state that allows operation.