ShineIn lighting controller

Machine vision light source controller collection driver

Open the plugin

Enter “Development Configuration → Collection Configuration”, create a device and select “ShineIn Light Source Controller” in “Collection Plugin”.

Supported channels and data types

Channel typePre-configuration check
TCP ClientConfirm network reachability of the device IP, port, and gateway to the device.
TCP serverConfirm that the local listening address and port are available, and allow on-site devices to actively connect to the gateway.
Serial PortConfirm that the serial port is not occupied by other programs and maintains the same baud rate, data bits, stop bits and parity bits as the device.

Optional data types: Boolean, Byte, Int16, UInt16, Int32, UInt32, Int64, UInt64, Float, Double, String, Decimal

This list describes types allowed by the plugin editor. Address width, arrays, string length and read/write restrictions still follow this page; it does not mean that every address supports every type.

Plugin properties

Protocol parameters

SettingDescription
Default channelDefault: 1; Range: 1~8; Fill in: text input. Sets the default channel used for protocol communication.

Connection configuration

SettingDescription
DTU IDFill in: text input. Sets the identifier used to identify the current device connection through the DTU service.

Address rules

  • Use Color, Light, LightDegree, WorkMode, Address, PulseWidth or Channel for the address. You can use c=2;Light to cover the reading channels from 1 to 8; the commonly used serial port parameters of the device are 57600 and 8E1.

Device debug

Enter “Development Configuration → Collection Configuration”, select the current device then open “Protocol Debug” at the top of the workspace.

ShineIn Light Source Controller: Read/Write

ShineIn Light Source Controller: Messages

Functions

FunctionPurpose
Read and writeRead a confirmed point and write only to an approved test point.
MessagesView sent and received frames, protocol fields, and error details.

Verify the configuration

Compare the raw level 1–3 with controller channel 1; this is not percentage brightness.

Troubleshooting

  • Use c=2;LightDegree for channel 2. Level, pulse-width and mode fields have distinct ranges.
  • The serial port device does not respond: Confirm that the serial port is not occupied, and check the baud rate, data bits, stop bits and parity bits.